The T1000 series sets a new precedent in its achievement of an innovative, compact design while maintaining enough clinical versatility to accommodate surgical procedures in nearly all fields, including urology, neurology, orthopedics, and cardiology.
maximum table load-bearing capacity 454 kg (1000 lb)
carbon fiber kidney elevator (X-ray penetration)
mechanic operation to control patient pressure
USB connection (e.g. for OR integration systems)
floor locks (electric-hydraulic) leveling floor unevenness up to 5 mm (method patented by AMTAI)
foot pump (secondary hydraulic drive)
X-ray screen guides (size 14 X-ray screens)
auto-diagnosis system (failure code screening and warning signal)
emergency button
leveling (table surface levels out according to natural gravity)
ergonomic design and illumination of the remote control
during operation, the T1000 table may be set in the normal position or in the reverse position (depending on the operation type and on the needs) (see additional crotch area apertures). The remote control includes two additional functions – “Normal” and “Reverse” to avoid confusion.
pressure-alleviating mattresses, 6 cm thick (seamless, water-tight, fire-resistant, antistatic and antibacterial). The mattresses provide ideal balance of pressure alleviation and low X-ray permeability, which protects the operating personnel against excessive X-ray doses
front-to-back slide up to 31 cm for maximum monitoring using the C arm
side protective guide (prevents tools from falling into the guides)
Designed to simplify patient positioning, the table also features a notably sturdy and low-profile base, ensuring surgeon comfort, thus reducing fatigue during long procedures.
The ergonomic hand pendant is backlit, facilitating its operation during endoscopic surgery.
The intelligent design of the table provides benefits such as remarkable C-arm access, self diagnosis with instant error code display, and the prevention of sectional conflict.
In addition to the durable, rust-free components, the T1000 also incorporates several fail-safe functions to ensure its continuous operation.
For T1000 tables with the slide option, the table can be slid in the leg direction. This allows convenient use of the C-arm when it is needed for some urology and gynecology procedures, without having to purchase any additional extenders.
Lateral Kidney and Thoracic
The patient can easily be situated laterally or in a supine position, and the use of the Flex function button and/or kidney elevator aids surgical access.
Seated Position
In reverse orientation, the table creates ample leg room while the patient is in a seated position, and the extensive articulation of the back section (which is the leg section in normal orientation).provides excellent surgical access. 30 degrees Trendelenburg movement forms an ideal angle for Extracorporeal Membrane Oxygenation (ECMO) procedures.
Cardiovascular
In normal orientation, by attaching the head section to the leg extension or by attaching the leg extension between the head and back sections, the T1000 Series provides unobstructed C-arm access for cardiovascular surgery and femoro-popliteal bypass surgery.
Shoulder Surgery
With the T1000 in reverse orientation, the leg extension is removed and the shoulder attachment is connected to the powered leg section, providing comfortable anterior and posterior access to the shoulder area with no movement required during surgery.
Nissen Fundoplication
The electro-hydraulically powered short leg section provides excellent support to the patient and is adjustable during surgery. This eliminates the need for reverse Trendelenburg straps and power-lift stirrups, while maintaining maximum endoscopic access to the esophagus and stomach area.
Total Hip Replacement
In reverse orientation and using the longitudinal slide, the patient can be positioned so that the location of the their hip is clear of the table base. This allows the C-arm to be comfortably used both laterally and vertically.
Rectal Surgery, Lumbar & Sacral Neurosurgery
With the appropriate accessories and the patient in kneeling position, the extraordinary height of the T1000 Series can easily meet the demands of rectal surgery also lumbar and sacrum vertebra Neurosurgery.
Ophthalmic and Plastic Surgery
With the combination of wide range of height adjustment and reverse orientation functions, the T1000 Series provides a comfortable working environment for a seated surgeon, and ample room for necessary equipment. With the “N” option, the height of the tabletop can be lowered to 55 cm above the floor.
Neurosurgery
In reverse orientation, the table creates ample space beneath the tabletop or the back section for prone, supine, lateral, or seated neurosurgery. Additionally, there is plenty of room to use the C-arm, including cases such as scoliosis where both vertical and horizontal imaging access is needed.